We run two fee for service laboratories based in Hobart and Perth. Our expertise is based around achieving results with high accuracy and precision at low concentration levels.

Equipment and analytical testing of water samples

Nutrients

In our labs we measure ammonium (NH4+), silicate (SiO44-), phosphate (PO43), nitrate+nitrite (NOx), and nitrite (NO2) at a wide range of micromolar concentrations.

We use a segmented flow auto analyser (Seal AA3).

We also offer in situ nutrient analysis for small field-based projects and high spatial resolution data requirements including the Seal AA100, Global FIA FloTracker, and Systea Wiz.

Nutrient Analysis by Seal AA3
  Silicate Phosphate Nitrate + Nitrite (NOx) Nitrite Ammonia
Analytical Range
(µmol L-1)
112 3 42 1.4 2.0
Method Detection Limit
(µmol L-1)
0.2 0.02 0.02 0.02 0.02
Uncertainty1
(actual @ 1 µmol L-1)
±0.017 ±0.024 ±0.019 ±0.14 ±0.302

Notes

  1. The reported uncertainty is an expanded uncertainty using a coverage factor of 2 giving a 95% level of confidence.
  2. The ammonia MU precision does not include data for the CRM.

Salinity

Salinity measurements are performed on a Guildline 8400 Autosal. This instrument measures conductivity, which is then converted to salinity in units of Practical Salinity Units (PSU).

All instruments are calibrated yearly by CSIRO’s Calibration Lab and are calibrated by the analyst prior to each analytical run.

  Measurement Range
Salinity 0.005 – 42.0 ± 0.001 PSU

Dissolved Oxygen

Dissolved oxygen is measured by UV titration. We use an instrument built by SCRIPPS Institution of Oceanography. The method our analysis uses is based on a whole-bottle modified Winkler titration of Carpenter (1965) with modifications by Culberson et al.

  Measurement Range
Dissolved Oxygen 0.2 – 200 µmol L-1

General Information

We can provide guidance and support for your sampling methodologies as well as storage, handing and transport advice.

Chain of custody practices ensure your sample integrity. You log your samples in via our website using your own sample numbers. Samples are checked upon receipt and comments logged.

Depending on samples, we can cater analysis/report turnaround time to your needs.

Accuracy and precision

If low level accuracy and precision are of concern, please speak to us prior to sampling so we can advise on best practices for sampling and storage.

Use this service

To engage Hydrochemistry services, please contact:

Contacts

Ms Cassie Schwanger

Hydrochemistry Team Leader (Oceans & Atmosphere)

Location

CSIRO Hobart
Castray Esplanade
Battery Point
Tas 7004

Contact us

Find out how we can help you and your business. Get in touch using the form below and our experts will get in contact soon!

CSIRO will handle your personal information in accordance with the Privacy Act 1988 (Cth) and our Privacy Policy.


First name must be filled in

Surname must be filled in

I am representing *

Please choose an option

Please provide a subject for the enquriy

0 / 100

We'll need to know what you want to contact us about so we can give you an answer

0 / 1900

You shouldn't be able to see this field. Please try again and leave the field blank.